Smk400 surface mounting kit provides for entry of surface wiring conduit. 15 through 20 for typical hookups.
Product Catalogue Morley Ias Pdf Pdf Document
Mi b501ap iv wiring diagram. Addressable fire alarm control panel detectors graphics modules networking voice alarm system esser. Once all detector bases have been wired and mounted and the loop wiring has been checked the detector heads may be installed in the bases. Break wire run to provide supervision of connections. Typical wiring diagram for 2 wire loop ululc listed compatible control panel caution. We will continue to try to get all the information that we can listed on this page. Caution disconnect power before wiring to prevent.
The mi dmmi and mi dmm2i monitor modules are used with the morley ias intelligent fire alarm control panels to provide a single or dual input circuit from external devices. Refer to table 4 for terminal designations. Do not loop wire under terminal 1 or 2. When installed in a b501ap base do not install detectors in locations where normal ambient temperature exceeds 50c page 2 of 6 990 1370311 wwwnotifi erfi resystemscouk. Lpcb ref199m02 other accessories. Use with most analogue or digital multimeters.
Renault car manuals pdf wiring diagrams above the page duster kajar kangoo koleos logan megane r5 clio captur master espace scenic talisman alaskan wind zoe thalia twizi velsatis fluence laguna. Follow equipment manufacturer wiring instructions when available. The chart and image above are correct for these models. A letter code is located near each terminal for identification. Changes to the status of the input circuits are communicated to the panel where. B501ap iv bk address tag height 225 mm weight 39 g installation instructions for b501ap iv bk and b524htr intelligent sensor bases before installing bases please thoroughly read system sensors guide to intelligent fire systems which gives information on sensor spacing placement zones and applications.
In 1898 the french company renault specializing in the manufacture of automobiles was foundedthe brand was founded by the brothers louis and marcel renault. B501ap iv bk meldersockel b501ap iv bk 102 mm. The list below offers some microphone wiring information. Each input is continuously monitored for normal open circuit and alarm conditions. 199b07 mi pse low profile intelligent optical sensor. 108ma at 24vdc versorgungsspannung.
Mod400r detector sensitivity test tool. Page 4 b501ap b524htr deutsch falls eine andere parallelanzeige eingesetzt werden soll ist sicherzustellen dass diese für den betrieb in verbindung mit den system sensor analogbrandmeldern geeignet ist. Mi ise low profile intelligent ionisation sensor. Mic wiring can be frustrating enough but when you cant find the right wiring info it is just impossible. Wiring all wiring must comply with local electrical codes and ordinances. Radio mic wiring diagram.
For use with b501 base only.