24 60 optimal operation narrative doors are to be normally held open. Relay output is designated as common.
Mitsubishi Galant Lancer Wiring Diagrams 1994 2003
Magnetic door lock wiring diagram pdf. An inswing mounting kit optional can be used when mounting on the hinge side of the door. Z4 magnet holding force 500kg 560kg dimensions l476 x h48 x d27 mm voltage 12vdc 24vdc 10 current 900ma at 12vdc 450ma at 24vdc monitoring hall effectbond sensing reed switch operating temperature 10 to 55 degrees operating humidity 0 95. Wired in series power supply for fail safe strikes and magnetic locks should be dc. A wiring diagram is a streamlined conventional pictorial depiction of an electrical circuit. It starts at the positive terminal of the power supply travels through the exit and entry switches into the positive terminal of the magnetic lock and out through the negative terminal of the mag back in through the negative terminal of the power supply. Wiring instructions magnetic lock or fail safe strike with button keypad maintained button and remote receiver.
The e600 series magnetic lock is mounted to the underside of the header on the stop side of the door. In the simple diagram above you can see that the electricity travels in an unbroken loop. This will conver t the ac to dc. Collection of magnetic door lock wiring diagram. Use a ul listed regulated power limited source. Pinstallation instelectromagnetic locksexcelinst e600vsd rev a3 05 18 page 1 any suggestions or comments to this instruction or.
Or double door locks should be installed with wiring covers in the middle so the magnet in one of the locks must be reoriented. Advanced features magnetic locks have no moving. Shown from exterior magnet wiring covers magnet. Same room install resistive. It shows the components of the circuit as simplified shapes and also the power as well as signal connections in between the gadgets. Magnetic bond sensor door position switch tri color led red or green both on yellow time delay 1 30 sec spdt dry spdt dry spdt dry 20 ma 40 ma 20 ma l 3 grn brn red bas bas dps led magnetic bond sensor door position switch tri color led red or green both on yellow spst no dry spdt dry 20 ma 40 ma all switches rated at 250 ma.
Z8 magnet holding force 1100kg 1160kg dimensions l532 x h72 x d40 mm voltage 12vdc 24vdc 10 current 1024ma at 12vdc 512ma at 12vdc. Magnetic locks should only be powered with dc voltage for proper operation. If this is not available you may use an ac power source and wire inline a full wave bridge rectifier. The electromagnetic door releases will be energized with the voltage shown. Refer to the installation wiring diagrams. Wiring cover magnet lhr door shown from exterior wiring cover magnet rhr door shown from exterior magnet should be placed opposite of door hinges.
Magnetic lock l z brackets for inswinging doors magnetic lock care and maintenance typical magnetic lock wiring magnetic lock electrical specifications am2370 for 300 pound magnetic lock am3370 for all 600 pound models of single magnetic locks am6370 for all 1200 pound models of single magnetic locks.