A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. 50 60 hz output output ratings.
Details About Icm Gemtech Universal Delay On Break Timer Relay 1 5 Min Icm203 Icm203b 1c320
Icm203 wiring diagram. Delay delay on break timers anti short cycle on delay on break helps to protect air conditioning refrigeration and heat pump equipment from damage which may be caused by the rapid short cycling of compressors. A wiring diagram is a simplified traditional pictorial representation of an electrical circuit. 1 amp minimum. Reapply power check operation. It is perfect to use when either a magnetic lock or electric strike is installed on an automatic door. 18 240 vac frequency.
For 120240 vac circuits cut the jumper wire. Icm controls icm203 icm203 delay on break timer 03 10 minute knob adjust. When the initiate contact closes the load energizes and remains energized as long as the initiate contact is closed. Delay on break delay on de energization. Delay on break timer with 03 10 minute adjustable time delay universal 18 240 vac. Select desired time delay adjustable models only.
Wiring diagram replaces thermal time delays off delay purges ducts of residual air to increase efficiency power must be applied before and during the time delay period. Mode of operation with application of power the load is energized. Buy icm controls icm203 delay on break timer 18 240 vac 125 height 2 width 2 length. Mode of operation upon application power the load is energized. Icm controls icm203 icm203 delay on break timer 03 10 minute knob adjust. Wiring diagram input 18 240 vac 1 2 3 load mode of operation installation specifications input voltage.
Ac air conditioning refrigeration and heat pump delay on break timer part icm203. Connect terminals as shown in the wiring diagram below. Select the desired time delay. Connect terminals as shown in the wiring. The compressor will not start again during the delay period. It shows the components of the circuit as simplified shapes and also the power and also signal links between the devices.
For 24 vac circuits apply control as packaged. Timing diagram icm controls. Delay on break timer wiring diagram. Control circuit wiresmode of operation. Connect terminals in series with the starting device as shown in the wiring diagram below. 10 amps time delay 10 1000 seconds timing diagram 1.
Collection of icm254 wiring diagram. 14 icms line voltage monitors were specifically. 40 ma inrush. When the thermostat opens or there is a loss of power the load is de energized and the delay period begins. Wiring diagram y r c tstat contactor compressor control transformer line voltage 1.