When reading through this operating instructions you will come across various symbols that require special. The software version can be seen from parameter 624.
Parameter Settings For Danfoss Vlt Hvac Drive 10v
Danfoss vlt 6000 wiring diagram. 345 terminal tightening torques 26 346 input line connection 26 347 motor wiring 26 348 grounding earthing 27 349 control wiring 27 3410 serial communication bus connection 28 3411 programming 28 4 start up 29 411 inspection before start up 30. 2x these operating instructions can be used with all cascade controller options with software version 2x. When this occurs the model can be identified by a vlt type 6xxx number. Vlt is a registered danfoss trademark5 general the specific installation instructions may vary depending upon the model of vlt 6000 series being installed. Vlt 6000 network wiring table ii. Accordance with customer connection diagram provided with option.
Page 84 6000 hvac series electrical installation power cables ip 00 and nema 1 ip 20 vlt 6042 6062 200 240 v ip 54 vlt 6042 6062 200 240 v compact ip 54 vlt 6102 6122 380 460 v mg61b502 vlt is a registered danfoss trademark. This number can be found on the red nameplate on the outside left side of the drive. Vlt 6000 dip switch settings switch setting switch 1 reservedno function switches 2 3 used for terminating an eia 485 interface. 15 block diagram of the frequency converter 4 16 enclosure types and power ratings 4. When the drive is the first last or only device on a network switches 2 and 3 must be on. Vlt 6000 hvac and vlt 8000 aqua operating instructions software version.
Operating instructions see the installation operation and maintenance manual document number 23 6108 00 for the vlt 6000 adjustable frequency drive for operating instructions. The vlt 6000 is in the inactive phase and has reached the end of its lifecycle. Danfoss offers an extensive portfolio of low voltage drives and can help you select the optimal replacement drive for your application. Wait at least 4 minutes. Mg14i102 vlt is a registered danfoss trademark 1. Using vlt6002 6005 200 240 v.
Note that terminal block tb1 tb2 etc is located in option enclosure. Vlt 5000 5000 flux 6000 hvac 8000 aqua profibus 4 mg90g102 vlt is a registered danfoss trademark. Vlt 6000 hvac introduction to hvac warning. Uration with a slave not manufactured by danfoss you should refer to the information in the respective manuals. Danfoss lifecycle management model recommends replacement using the drivepro retrofit service. Vlt 6000 dip switch n eia 485 p eia 485 figure 5.
175ha49011 touching the electrical parts may be fatal even after the equipment has been disconnected from mains. 44 wiring schematic 12 45 access 14 46 motor connection 14 47 ac mains connection 15 48 control wiring 16 481 control terminal types 16.