Do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Can prevent a system from responding properly in the event of a fire.
Loop Drawing Electrical Wiring Picture 2326644 Loop Drawing
System sensor wiring diagram. The 2 wire products fit systems where a single nac controls both horn and strobe. Cop ies of this manual are available at no charge from system sensor. Wiring diagram for rts451 to dh100acdc 4 wire duct smoke detector figure 3. All spectralert advance products are suitable for use in synchronized systems. System sensor smoke detector wiring diagram. Resetting only certain system sensor models of detectors.
System sensor is a global manufacturer of fire and life safety devices in smoke detection carbon monoxide detection and notification technology. Nfpa standards 72 and 90a should also be refer enced for detailed information. System sensor model beam1224beam1224s is a long range projected beam smoke detector designed to provide open area protection. Nfpa standards 72 and 90a should also be referenced for detailed information. A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. It is to be used with ul listed separately supplied power 4 wire control panels only.
The system sensor mdl3 module may be used to provide synchronization. Wiring diagram for rts451 to dh100 2 wire duct smoke detector 15 20 2 11 2 alarm signal 1 aux. Power reset test red led alarm. It shows the elements of the circuit as simplified forms and the power as well as signal links in between the gadgets. Please thoroughly read the system sensor manual i56 407 guide for proper use of system smoke detectors which provides detailed information on detector spacing placement zoning wiring and special applications. System sensor smoke detector wiring diagram a novice s guide to circuit diagrams.
The detector consists of a transmitterreceiver unit and a reflector. Assortment of system sensor smoke detector wiring diagram. The 4 wire products are in tended for systems which have separate wiring circuits for the horn and strobe. Read system sensors applications guide for duct smoke detectors hvag53 which provides information on detector spacing placement zoning wiring and special applications. Refer to detector installation instructions for additional information. Please also refer to canulc s524 standard for.
The non polarized screw terminals on the back of the detector will accept 1422 awg wire. Psp1 products system sensor system sensor. An initial appearance at a circuit representation could be confusing however if you could read a metro map you could read schematics. For best system performance all wiring should be installed in separate grounded conduit. Read the system sensor guide for proper use of smoke detectors in duct applications a05 1004 which provides information on detector spac ing placement zoning wiring and special applications.