Rts151key and a unit complete with backbox to be used for surface mounting part no. Power reset test red led alarm dh100acdc rts151 5 4 3 reset field installed jumper 1 2 3 4 5 6 3 4 test 5 test reset reset test ra 1 reset ra 2 v out dh100 rts151 6 alarm led no connection h0198 04 h0612 11 h0197 01 figure 7.
Bca 4 Wire Smoke Detector Wiring Diagram Detectors Even
Rts151key wiring diagram. A 3 wire connection provides a reset switch operation and alarm led signaling. For 2 wire detectors the led illuminates red for alarm. Everything you need to know duration. The rts151keya mounts to a single gang box 2 1 2 mini mum depth or directly to the wall or ceiling. For the applicable wiring diagram. In canadian applications the rts151key is intended to be located in the same room as the smoke detector and within 60 feet of the unit.
The rts151 and rts151key remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. Wiring diagram for rts151 to dh100 2 wire duct smoke detector. In canadian applications the rts151key a is intended to be located in the. Installation there are 2 possibilities to wire the osi 90 and osi 10 imagers to the rts150key unit. Two versions are available. Capability with the rts451rts151 or rts451keyrts151key remote test stations.
15 19 14 3 20 2 11 2 6 alarm signal 1. 14 to 35 vdc 12 ma max. Wiring duct smoke detector a day in the life episode 25 3 9 15 duration. Temperature range 14f to 140f 10c to 60c. The rts151key a mounts to a single gang box 2 mum depth or directly to the wall or ceiling. The rts151key mounts to a single gang box 2 12 minimum depth or directly to the wall or ceiling.
In canadian applications the rts151keya is intended to be located in the same room as the smoke detector and within 60 feet of the unit. Alarm response time 40 seconds max. A flush mount unit part no. 15 20 2 11 2 alarm signal 1 aux. 21 detector feature set utilizes plug in head part number sk photor sampling tubes install from front and rear compatible with existing accessories able to address detector per code switches on sensor head. Wiring diagram for rts151 to dh400acdc duct.
3 contents of the duct smoke. Stephen rardon 36926 views. In canadian applications the rts451keya is intended to be located in the same room as the smoke detector and within 60 feet of the unit. The rts451key mounts to a single gang box 21 2 minimum depth or directly to the wall or ceiling. 28 to 32 vdc 12 ma max. Off reset test h0195 01 h0582 12 figure 1.
For 4 wire detectors the rts151key test station features a multi colored led that alternates between steady green and red. Wire gauge 14 to 18 awg dimensions 48h x 29w x 14d ra100zwmf rts151wmf rts151keywmf rts151key remote test station with key power requirements power led green.