The accessory terminals will accept 2 14 12 alcu. Shunt trip breaker wiring diagram this post is about the single wiring diagram of mccb shunt trip breaker.
Patent Us7471195 Emergency Power Shutdown Management System
Epo shunt trip wiring diagram. The epo box should have a set of connections for each device served. There are no shop drawings showing wiring diagrams location of devices and intended sequence of operation. Shunt tr at electrical specifications. Sump pump installation diagram tripwire diagram shunt breaker wiring epo switch wiring diagramepo switch wiringshunt trip breakerplease provide a field wiriing diagram for connecting an epo in a data center to a trane model xxxxx so that the crac unit will shut down when the epo is engaged. Thanks harry304e for the pertinent information. An eposhunt trip situation where there are multiple epo switches say three and the shunt trip coil circuit is powered from two phases of the same 480v circuit as powers the power circuit but is stepped down to 120v by transformer ahead of the epo switches and.
Moreover the systems are rarely documented. In industrial state electric operator duty is to operate the machinery and his duty is on the front of main panel board. Shunt trip device black wires maximum permissible voltage is 110 of rated for ac 125 for dc. Power circuits feeding shunt trip breakers are unidentified and unmonitored. The shunt trip allows the circuit breaker to be tripped table i. Loss of the epo circuit supply voltage loose wiring or conductors in the epo circuit a blown fuse in the epo circuit.
Which is also known with the name of kill switch. Shunt trip accessories in qob are factory installed only and can not be added to an existing breaker. Several fault conditions can create a situation where the epo will not operate to shut off the circuit. Be it 24v 48v or 120v. The breaker shunt trip coil is controlled by the emergency switch. The shunt trip breaker has to be selected and rated to match the box output voltage.
In the diagram a mccb molded case circuit breaker shown which is wired for 3 phase system. In this post i am just tell you about wiring of single epo button with shunt trip mccb breaker. Any such online diagram for the following variation would also be of interest. I could not find this anywhere on line. Shunt trip breaker wiring diagram with epo button. Electrically from a remote location by application of control voltage to the accessory leads.
Additionally no maintenance bypass switch is installed that would allow the epo to be defeated during routine. You will run these wires to the shunt trip and it should work the same way. The shunt trip has coil clearing contacts that open when the voltage is applied so either momentary or maintained contacts can be used to initiate voltage. Shunt trip coil epo button push to close the traditional epo circuit is not fail safe however.