Boilermate 2000 the boilermate 2000 shown schematically above is designed to provide improved space heating and mains pressure hot water when coupled to any remotely sited condensing or non condensing boiler. See section 13 system remote.
Ask Glow Worm
Boilermate wiring diagram. I am think of using a 8148a and was wondering if i need to have a zone valve controlling the boiler mate circulator. Boilermate deaerator drawings 430 gal dxf drawings for the boilermate deaerator 430 gal in dxf format boilermate deaerator drawings 800 gal dxf drawings for the boilermate deaerator 800 gal in dxf format c1x flow dia hw return drawing drawings for condensing economizer model c1x flow dia hw return. Dpdt relay aquastat boilermate circulator coil 2 1 3 4 6 5 honeywell r4222d 1013 or. The diagram below shows internal wiring and the associated functions. 35 electricity supply and wiring diagrams 17 36 appliance controller 19 361 appliance selection 19 362 display in normal mode 19 363 sensor temperature reading 19 364 control temperature set point reading 19 365 fault code indication 19 366 computer interface 22 40 heating and hot water. Compared to tankless water heaters boilermate operates efficiently while adding a storage buffer for whole family hot water needs.
The smart control incorporates all the switching and temperature control functions necessary to control the boilermate. Select the appropriate diagram for the application. The aquastat is a hw8184a and it has a chattering relay and needs replacement. Boilermate 2000 and the deciding factor is the space heating and the hot water requirements of a dwelling. A report by the cranfield institute of technology found that this system gives a potential for energy savings of up to 15. If your application is not shown contact amtrol technical support at 4015351216.
After wiring is complete insert the white thermistor sensor plug into the receptacle at the base of the smart control. I looked at my wiring diagrams and can not find one showing a boilermate model wh 7p being used with a taco zone valve. More efficient than conventional gas or electric water heaters boilermate indirects provide more hot water use less energy and require no venting or additional utility connections. Wiring a digital control to a boiler supplied control with boilermate duration. Amtrol boilermate rtr installation operation manual 32 pages indirect fired water heaters installation operation maintenance instructions. The boilermate 2000 is available with the option of switch which will provide a 9kw electrical emergency backup in case of failure of the main heat source.
Diagrams are popular examples only. See section 12 technical data for further details. Mechanical aquastat wiring diagrams 5 common wiring diagrams are shown below.