Surface mounted electrical boxes smb500 are available. Monitor modules supervise a circuit of dry contact input devices such as conventional heat detectors and pull stations or monitor and power a circuit of two wire smoke detectors.
Fire Alarm Panel Notifier N 6000
Notifier mmx 1 wiring diagram. Notifier fcm 1 wiring diagram. The monitored circuit may be wired as an nfpa style b class b or style d class a ini tiating device circuit. The fmm 1a can be used to replace mmx 1a modules in existing systems. The box must have a minimum depth of 21 8. Releasing applications c limited energy cable cannot be used to wire a. May also be used to monitor normally open supervisory devices with special.
16112018 16112018 3 comments on notifier fcm 1 wiring diagram. Fzm 1 applications use the fzm 1 to monitor a zone of two wire smoke detectors. The smb500 may then be installed in a 19 rack assembly using notifier 19 rack mounting adapters. Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. All wiring must conform to applicable local codes ordinances and regulations. Connecting a releasing device to the fcm 1 rel.
When using control modules in nonpower limited applica. Install contact closure devices per manufacturers installation instructions. Mmx 1e sem screws with clamping plates for ease of wiring mmx 1e lpcb and vds approved installation the mmx 1e mounts in the notifier multi mount enclosure or an smb500. Compatible notifier system control panels only list available from notifier. All wiring must conform to applicable local codes ordi. Monitor modules model numbers include the fmm 1 fmm 101 fzm 1 and fdm 1.
The box must have a minimum depth of 218. Notifier nfse manual online. Notifier nfs manual online. Any number of ul listed contact closure devices may be used. Fzm 1 has a panel controlled led indicator and can be used to replace mmx 2 modules in existing systems. Mounting mmx 1a cmx 2a and iso x devices mmx 1a cmx 2a and iso x modules mount directly to 4 inch square electri cal boxes as shown in figure 2a.
All wiring must conform to applicable local codes ordi. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. A 39 k ohm end of line resistor pro. Notifiers offers a variety of intelligent monitor modules for diverse applications. Set the address on the module per job drawings. The mmx 102e mounts in a standard single gang electrical knock.
Fmm 1 connect modules to listed compatible notifier control panels only. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. The box must have a minimum depth of 218. Surface mounted electrical boxes smb500 are available from notifier. Fmm 1a applications use to monitor a zone of four wire smoke detectors manual fire alarm pull stations waterflow devices or other normally open dry contact alarm activation devices. Page 5 wiring diagrams this page.
Connecting a releasing device to a fcm 1 module connecting an. Compatible notifier system control panel list available from noti fier. All wiring must conform to applicable local codes ordinances and regulations. All wiring shown is supervised and power limited. This module is intend ed for power limited wiring only.